An efficient and green method for the analysis of synthetic cathinones in whole blood using 96-well electromembrane extraction and LC-MS/MS

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

An efficient and green method for the analysis of synthetic cathinones in whole blood using 96-well electromembrane extraction and LC-MS/MS. / Fabris, André L.; Hansen, Frederik A.; Yonamine, Mauricio; Pedersen-Bjergaard, Stig; Øiestad, Elisabeth L.

In: Sustainable Chemistry and Pharmacy, Vol. 38, 101494, 2024.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Fabris, AL, Hansen, FA, Yonamine, M, Pedersen-Bjergaard, S & Øiestad, EL 2024, 'An efficient and green method for the analysis of synthetic cathinones in whole blood using 96-well electromembrane extraction and LC-MS/MS', Sustainable Chemistry and Pharmacy, vol. 38, 101494. https://doi.org/10.1016/j.scp.2024.101494

APA

Fabris, A. L., Hansen, F. A., Yonamine, M., Pedersen-Bjergaard, S., & Øiestad, E. L. (2024). An efficient and green method for the analysis of synthetic cathinones in whole blood using 96-well electromembrane extraction and LC-MS/MS. Sustainable Chemistry and Pharmacy, 38, [101494]. https://doi.org/10.1016/j.scp.2024.101494

Vancouver

Fabris AL, Hansen FA, Yonamine M, Pedersen-Bjergaard S, Øiestad EL. An efficient and green method for the analysis of synthetic cathinones in whole blood using 96-well electromembrane extraction and LC-MS/MS. Sustainable Chemistry and Pharmacy. 2024;38. 101494. https://doi.org/10.1016/j.scp.2024.101494

Author

Fabris, André L. ; Hansen, Frederik A. ; Yonamine, Mauricio ; Pedersen-Bjergaard, Stig ; Øiestad, Elisabeth L. / An efficient and green method for the analysis of synthetic cathinones in whole blood using 96-well electromembrane extraction and LC-MS/MS. In: Sustainable Chemistry and Pharmacy. 2024 ; Vol. 38.

Bibtex

@article{16d3b49fc1ed4c30a2f03927f886d3af,
title = "An efficient and green method for the analysis of synthetic cathinones in whole blood using 96-well electromembrane extraction and LC-MS/MS",
abstract = "Electromembrane extraction (EME) is a miniaturized technique in which charged molecules are extracted from biological samples, through a porous membrane, into an acceptor solution. This process occurs in the presence of an electric field that enables increased analyte recovery in short extraction times. Studies are being carried out to establish recommended extraction conditions for different groups of compounds based on their physicochemical properties. In this work, pre-established generic liquid membranes for the extraction of basic compounds were tested using synthetic cathinones within a wide log P range as basic model analytes. First, recommended organic solvents for the chosen analytes were evaluated in terms of recovery. The best candidates were included in an optimization study with other relevant EME conditions (voltage, extraction time, and agitation rate). All analyses were performed using a UPLC-MS/MS with the multiple reaction monitoring mode. 2-Undecanone was chosen as the liquid membrane providing the best extraction efficiency in combination with 40 V, 35 min, and 725 rpm. Validation showed r2 > 0.99 in the 1–500 ng/mL range, accuracy of ±12%, imprecision of ≤19%, 1 ng/mL as limit of quantitation, 0.1–0.5 ng/mL as limit of detection, matrix effect 97–118%, and recovery 63–110%. Among the generic liquid membranes studied in this work, 2-Undecanone was the best choice for the target basic analytes. High recoveries and low matrix effects were achieved, thus demonstrating the applicability of recommended generic liquid membranes in the 96-well plate setup and with whole blood samples. Our findings contribute to further establishing EME as an actual sample preparation technique for routine analyses that could be further explored in a commercial format.",
keywords = "Electromembrane extraction, LC-MS/MS, New psycoactive substances, Synthetic cathinones",
author = "Fabris, {Andr{\'e} L.} and Hansen, {Frederik A.} and Mauricio Yonamine and Stig Pedersen-Bjergaard and {\O}iestad, {Elisabeth L.}",
note = "Funding Information: The funding from Coordena{\c c}{\~a}o de Aperfei{\c c}oamento de Pessoal de N{\'i}vel Superior ( CAPES - PDSE/PrInt) [ 30/2022 ] is gratefully acknowledged. Publisher Copyright: {\textcopyright} 2024 The Authors",
year = "2024",
doi = "10.1016/j.scp.2024.101494",
language = "English",
volume = "38",
journal = "Sustainable Chemistry and Pharmacy",
issn = "2352-5541",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - An efficient and green method for the analysis of synthetic cathinones in whole blood using 96-well electromembrane extraction and LC-MS/MS

AU - Fabris, André L.

AU - Hansen, Frederik A.

AU - Yonamine, Mauricio

AU - Pedersen-Bjergaard, Stig

AU - Øiestad, Elisabeth L.

N1 - Funding Information: The funding from Coordenação de Aperfeiçoamento de Pessoal de Nível Superior ( CAPES - PDSE/PrInt) [ 30/2022 ] is gratefully acknowledged. Publisher Copyright: © 2024 The Authors

PY - 2024

Y1 - 2024

N2 - Electromembrane extraction (EME) is a miniaturized technique in which charged molecules are extracted from biological samples, through a porous membrane, into an acceptor solution. This process occurs in the presence of an electric field that enables increased analyte recovery in short extraction times. Studies are being carried out to establish recommended extraction conditions for different groups of compounds based on their physicochemical properties. In this work, pre-established generic liquid membranes for the extraction of basic compounds were tested using synthetic cathinones within a wide log P range as basic model analytes. First, recommended organic solvents for the chosen analytes were evaluated in terms of recovery. The best candidates were included in an optimization study with other relevant EME conditions (voltage, extraction time, and agitation rate). All analyses were performed using a UPLC-MS/MS with the multiple reaction monitoring mode. 2-Undecanone was chosen as the liquid membrane providing the best extraction efficiency in combination with 40 V, 35 min, and 725 rpm. Validation showed r2 > 0.99 in the 1–500 ng/mL range, accuracy of ±12%, imprecision of ≤19%, 1 ng/mL as limit of quantitation, 0.1–0.5 ng/mL as limit of detection, matrix effect 97–118%, and recovery 63–110%. Among the generic liquid membranes studied in this work, 2-Undecanone was the best choice for the target basic analytes. High recoveries and low matrix effects were achieved, thus demonstrating the applicability of recommended generic liquid membranes in the 96-well plate setup and with whole blood samples. Our findings contribute to further establishing EME as an actual sample preparation technique for routine analyses that could be further explored in a commercial format.

AB - Electromembrane extraction (EME) is a miniaturized technique in which charged molecules are extracted from biological samples, through a porous membrane, into an acceptor solution. This process occurs in the presence of an electric field that enables increased analyte recovery in short extraction times. Studies are being carried out to establish recommended extraction conditions for different groups of compounds based on their physicochemical properties. In this work, pre-established generic liquid membranes for the extraction of basic compounds were tested using synthetic cathinones within a wide log P range as basic model analytes. First, recommended organic solvents for the chosen analytes were evaluated in terms of recovery. The best candidates were included in an optimization study with other relevant EME conditions (voltage, extraction time, and agitation rate). All analyses were performed using a UPLC-MS/MS with the multiple reaction monitoring mode. 2-Undecanone was chosen as the liquid membrane providing the best extraction efficiency in combination with 40 V, 35 min, and 725 rpm. Validation showed r2 > 0.99 in the 1–500 ng/mL range, accuracy of ±12%, imprecision of ≤19%, 1 ng/mL as limit of quantitation, 0.1–0.5 ng/mL as limit of detection, matrix effect 97–118%, and recovery 63–110%. Among the generic liquid membranes studied in this work, 2-Undecanone was the best choice for the target basic analytes. High recoveries and low matrix effects were achieved, thus demonstrating the applicability of recommended generic liquid membranes in the 96-well plate setup and with whole blood samples. Our findings contribute to further establishing EME as an actual sample preparation technique for routine analyses that could be further explored in a commercial format.

KW - Electromembrane extraction

KW - LC-MS/MS

KW - New psycoactive substances

KW - Synthetic cathinones

U2 - 10.1016/j.scp.2024.101494

DO - 10.1016/j.scp.2024.101494

M3 - Journal article

AN - SCOPUS:85188201111

VL - 38

JO - Sustainable Chemistry and Pharmacy

JF - Sustainable Chemistry and Pharmacy

SN - 2352-5541

M1 - 101494

ER -

ID: 387021498